Results 1 to 12 of 12

Thread: New Special Ranges - Coordination Thread

  1. #1

    Arrow New Special Ranges - Coordination Thread

    I've created 2 worktodos that have ranges that weren't P-1 tested but are now back in the first-pass queue.

    A lot of these tests are for k=21181 because it wasn't done to the same levels with all the other k values due to a queuing bug awhile back. Anyway, here are a few hundred tests that would be really great to put priority on.

    Some of the tests near the bottom of the lower file might still get passed but since it's first-pass, it wouldn't be terrible if they get done eventually because otherwise they will require double-checks anyway.

    Thanks to those of you who can help with these important manual P-1 tests.

    Cheers,
    Louie
    Attached Files Attached Files

  2. #2
    Reserving from the "new" files:
    Code:
    Pminus1=N/A,10223,2,14109101,1,130000,2200000
    Pminus1=N/A,55459,2,14109058,1,130000,2200000
    Pminus1=N/A,22699,2,14109022,1,130000,2200000
    Pminus1=N/A,10223,2,14108969,1,130000,2200000
    Pminus1=N/A,21181,2,14108780,1,130000,2200000
    Pminus1=N/A,55459,2,14108386,1,130000,2200000
    Pminus1=N/A,10223,2,14106725,1,130000,2200000
    Pminus1=N/A,24737,2,14105863,1,130000,2200000
    Pminus1=N/A,10223,2,14105405,1,130000,2200000
    Pminus1=N/A,24737,2,14103703,1,130000,2200000
    Pminus1=N/A,24737,2,14103463,1,130000,2200000
    Pminus1=N/A,24737,2,14103103,1,130000,2200000

  3. #3
    Member
    Join Date
    Jan 2003
    Location
    Norway
    Posts
    61
    14492407 14999780 shauge ? [reserved] (from new special range)

  4. #4
    Quote Originally Posted by Rincewind View Post
    Reserving from the "new" files:
    Code:
    Pminus1=N/A,10223,2,14109101,1,130000,2200000
    Pminus1=N/A,55459,2,14109058,1,130000,2200000
    Pminus1=N/A,22699,2,14109022,1,130000,2200000
    Pminus1=N/A,10223,2,14108969,1,130000,2200000
    Pminus1=N/A,21181,2,14108780,1,130000,2200000
    Pminus1=N/A,55459,2,14108386,1,130000,2200000
    Pminus1=N/A,10223,2,14106725,1,130000,2200000
    Pminus1=N/A,24737,2,14105863,1,130000,2200000
    Pminus1=N/A,10223,2,14105405,1,130000,2200000
    Pminus1=N/A,24737,2,14103703,1,130000,2200000
    Pminus1=N/A,24737,2,14103463,1,130000,2200000
    Pminus1=N/A,24737,2,14103103,1,130000,2200000

    Why did you add in "N/A" as the key? Those lines are cool if you're doing it strickly offline, but if you're using the server, it will not like that key and tell you your work is no longer needed when it submits... if you're doing it online, use the key 000000000000000000000000000ED0A5, not N/A.

    Cheers,
    Louie

  5. #5
    I took the candidates from the file without changing them.

    I have to cancel this range, because I have an unstable system at the moment (I don't know why, maybe the temperature?) And it could take a while for me to fix it.
    I just finished
    Pminus1=N/A,10223,2,14109101,1,130000,2200000, no factor.

    But for the next time I'll change the key.

  6. #6
    Quote Originally Posted by Rincewind View Post
    I took the candidates from the file without changing them.
    ...
    But for the next time I'll change the key.
    This is how they appear in the file I uploaded:

    Quote Originally Posted by worktodo_14100000_15000000.txt
    Pminus1=10223,2,14109101,1,130000,2200000
    Pminus1=55459,2,14109058,1,130000,2200000
    Pminus1=22699,2,14109022,1,130000,2200000
    Pminus1=10223,2,14108969,1,130000,2200000
    Pminus1=21181,2,14108780,1,130000,2200000
    Pminus1=55459,2,14108386,1,130000,2200000
    Pminus1=10223,2,14106725,1,130000,2200000
    Pminus1=24737,2,14105863,1,130000,2200000
    Pminus1=10223,2,14105405,1,130000,2200000
    Pminus1=24737,2,14103703,1,130000,2200000
    Pminus1=24737,2,14103463,1,130000,2200000
    Pminus1=24737,2,14103103,1,130000,2200000
    That's why I thought it was weird that you had added "N/A" as a key. Is this worktodo format outdated for use with the stand-alone factoring clients now?

    Cheers,
    Louie

  7. #7
    Member
    Join Date
    Jan 2003
    Location
    Norway
    Posts
    61
    Quote Originally Posted by jjjjL View Post
    That's why I thought it was weird that you had added "N/A" as a key. Is this worktodo format outdated for use with the stand-alone factoring clients now?

    Cheers,
    Louie
    I don't think there is anything wrong with your fileformat. It works for me with Prime95 version 25.8.
    I saw the Prime95 added that to my worktodo file too, one time when I accidently got it into some kind of online mode.

  8. #8
    Member
    Join Date
    Jan 2003
    Location
    Norway
    Posts
    61
    15000000 16000000 shauge ? [reserved] (from new special range)

  9. #9
    Member
    Join Date
    Jan 2003
    Location
    Norway
    Posts
    61
    14492407 14999780 shauge 13 [complete] (from new special range)

  10. #10
    Member
    Join Date
    Jan 2003
    Location
    Norway
    Posts
    61
    Quote Originally Posted by shauge View Post
    15000000 16000000 shauge ? [reserved] (from new special range)
    I have already done all tests within the range 15000000-15500000 and will do the rest within a week, so there is no apparent danger of being passed by PRP.

  11. #11
    Member
    Join Date
    Jan 2003
    Location
    Norway
    Posts
    61
    15000000 16000000 shauge 31 [complete] (from new special range)

  12. #12
    Member
    Join Date
    Jan 2003
    Location
    Norway
    Posts
    61
    All the tests with k=21181 I have found a factor for, except one, had already had 1 PRP test run on them priory. Did you put too many tests in those worktodo.txt files, Louie?
    This would also explain why there are several thousand tests instead just of a few hundred as first announced.

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •